CBVLW - CEE-BEE A-215

  • MSDS: CBVLW
  • Manufacturer: MCGEAN ROHCO INC
  • Product Name: CEE-BEE A-215
  • National Stock Number: 8010-00N000304
Product Identification

Product ID:CEE-BEE A-215
MSDS Date:01/01/1990
FSC:8010
NIIN:00N000304
MSDS Number: CBVLW

Responsible Party
MCGEAN-ROHCO INC
9520 EAST CEE BEE DR
DOWNEY, CA 90241
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 213-803-4311

Preparer: H B HANS

Cage: 71361

Contractor
MCGEAN-ROHCO INC
DOWNEY, CA 90241-5501 US

Telephone: 562-803-6701

Cage: 71361

Ingredients

METHANE, DICHLORO-; (METHYLENE CHLORIDE) (SARA 313)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 40-65%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM, A2

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PHENOL (SARA 302/313) (CERCLA)

CAS: 108-95-2

RTECS: SJ3327000

Fraction By Weight: 10-30%

OSHA PEL 5 PPM, S

ACGIH TLV: 5 PPM, S

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


CHROMIC ACID, DISODIUM SALT; (SODIUM CHROMATE) (SARA 313)

CAS: 7775-11-3

RTECS: GB2955000

Fraction By Weight: <1.5%

OSHA PEL C 0.1 MG (CRO3)/M3

ACGIH TLV: 0.05 MG(CR)/M3; A1

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CORROSIVE TO EYES AND SKIN.
READILY ABSORBED THROUGH THE SKIN. VAPORS CAN CAUSE DIZZINESS,
NAUSEA. CHRONIC: CAN CAUSE DAMAGE TO LIVER, KIDNEYS OR BLOOD.
CHLOROCARBON MATERIALS HAVE PRODUCED SEN SITIZATION OF THE
MYOCARDIUM TO EPINEPHRINE IN LABORATORY ANIMALS AND COULD HAVE A
SIMILAR EFFECT IN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: IARC MONO, SUPP, VOL
7, PG 194, 1987: GROUP 2B. NTP 7TH ANNUAL REPORT ON CARCINS, 1994:
(SUP DAT)
Effects of Overexposure:HLTH HAZ: HUMANS. ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES
IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES/SKIN: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. GET
MEDICAL ATTENTION. INHALATION: REMOVE TO FRESH AIR. IF SYMPTOMS
PERSIST, GET MEDICAL ATTENTION. INGESTION: CALL MD IMMEDIATELY .

Fire Fighting

Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE .

Accidental Release

Spill Release Procedures:ABSORB WITH ABSORBENT MATERIAL, SUCH AS
VERMICULITE. PLACE IN SUITABLE, CLOSED CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN CLOSED CONTAINERS IN COOL
(32F-90F), DRY, WELL-VENTILATED AREA. OPEN CONTAINERS SLOWLY AND
WITH CAUTION.
Other Precautions:MO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED ORGANIC CARTRIDGE
RESPIRATOR.
Ventilation:SUFFICIENT TO KEEP BELOW TLV LIMITS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:SUFFICIENT TO PREVENT SKIN CONTACT.
EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPEC GRAV: 1.22 (BOTTOM LAYER). PH: 10-11 (WATER PHASE). CARCIN EXPLAN:
ANTIC TO BE CARCIN. ANIMAL: LUNG, LIVER, SALIVARY, MAMMARY GLAND
(TUMORS). SODIUM CHROMATE: IARC MONO ON EVALUATION OF CARCIN RI SK
OF CHEMICALS TO MAN, VOL 49, PG 49, 1990: GROUP 1. NTP 7TH ANNUAL
REPORT ON CARCINS, 1994: KNOWN TO BE CARCINOGEN.

Chemical Properties

Boiling Pt:B.P. Text:103F,39C
Vapor Density:2
Spec Gravity:SUP DAT
pH:SUPDAT
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:TWO-PHASE LIQUID, WITH PHENOLIC ODOR

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:DIRECT CONTACT WITH OPEN FLAME COULD
FORM PHOSGENE. HCL .

Disposal

Waste Disposal Methods:RECLAIM SOLVENTS BY DISTILLATION OR BURN IN AN
APPROVED INCINERATOR, OR SEND TO EPA APPROVED WASTE DISPOSAL
FACILITY. DISPOSE OF IN ACCORDANCE W/LOCAL, STATE & FEDERAL
REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.